FhSim  3.1.0
Marine systems simulation
Loading...
Searching...
No Matches
NetPanelOptions Struct Reference

What a net panel adds beyond its load and weight in water. Net/NetStructure uses the defaults.

#include <NetElement3N.h>

Public Attributes

bool twineStructure = true
 
double dampingRatio = 1.0
 NetDampingRatio: the damping ratio of the panel's stiffest stretch mode, 1 = critical. The twine tension gets a Kelvin-Voigt dashpot, T = max(0, EA (L - L0 + tau rate) / L0) per bar family, tau = 2 * it * sqrt(m / k) (net_element_forces::PanelTensionDampingTime); the old isotropic relative-velocity term (2 * it * sqrt(m) kg/s, about 1 % of critical on the stretch mode) stays and damps the soft modes. Unused without twineStructure.
 

Member Data Documentation

◆ twineStructure

bool NetPanelOptions::twineStructure = true

Twine tension (EA) and structural damping. False in Net/NetStructureWithConstraints: an adapter choice (owner ruling Q3d, 2026-10-14), the constraint solver holds the lengths. Off skips both terms, so the panel adds its load law's force and its weight in water only.


The documentation for this struct was generated from the following file: