Simulation of a 4-stroke CI engine.
- Author
- Per Rundtop
- Warning
- This implementation must be verified, at least with the provided input file
<Contents>
<OBJECTS>
<Lib LibName="maritime"
SimObject="CIEngine"
ModParFilename="../../../examples/input/engine/CIParameters.xml"
Name="CI"
/>
<Lib LibName="base"
SimObject="Src/Step"
Name="Step1"
StartValue="5000"
StopValue="11500"
StartTime="35"
StopTime="60"/>
<Lib LibName="base"
SimObject="Src/Step"
Name="Step2"
StartValue="13.33"
StopValue="20"
StartTime="20"
StopTime="80"/>
</OBJECTS>
<INTERCONNECTIONS>
<Connection
CI.M_load="Step1.Out"
CI.N_eng_SP="Step2.Out"
CI.pInM_SP="2.5e5"
CI.MinLambda_SP="1.5"
/>
</INTERCONNECTIONS>
<INITIALIZATION>
<InitialCondition
CI.p_InM="1e5"
CI.p_ExM="1e5"
CI.N_eng="1"
CI.N_TC="100"
CI.PI_N_eng="1e-3"
CI.PI_Lambda="2e-3"
CI.PI_WG="1"
/>
</INITIALIZATION>
<SIMULATION>
<Timing TStart="0" TEnd="80"/>
<Integrator Method="RK45_i">
<StepControl Step="1e-4" StepMax="100" StepMin="0.000001" AbsTol="1e-7" RelTol="1e-7"/>
</Integrator>
</SIMULATION>
<OBSERVERS>
<FileOutput TOutput="0, 0:0.1:80, 80" Select="objects:all"/>
</OBSERVERS>
</Contents>
This SimObject is referred to as CIEngine